Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 20 de 29
Filter
1.
Sensors and Actuators B: Chemical ; : 133939, 2023.
Article in English | ScienceDirect | ID: covidwho-2311807

ABSTRACT

Nucleic acid testing (NAT) is directly oriented to determining the genetic material of pathogens and is characterized by its high sensitivity and specificity, which are indispensable qualities in disease diagnosis. However, standard laboratory NAT methods require joint testing by highly trained inspectors using multiple instruments in professional laboratories. The entire process requires many manual steps, and the total testing time may range from 3 to 5h, indicating that these methods cannot be used to realize the demands of on-site rapid testing. In this study, we propose a microfluidic chip for the on-site and rapid detection of nucleic acids. We utilize dynamic sealing, ultrasound, and advanced control methods and integrate the entire process of reagent pre-storage, extraction, Real-time Quantitative polymerase chain reaction (qPCR), and fluorescence detection. The sensitivity of this system is in line with current clinical standards, and the nucleic acid quantification process is completed fully automated within 30min. Compared with conventional microfluidic chips, the proposed system has the advantages of high integration, low cost, and it may be produced at a high volume. Moreover, it can be used in a wide range of screening cases in the context of the COVID-19 pandemic and exhibits broad clinical application prospects.

2.
J Funct Biomater ; 14(4)2023 Apr 09.
Article in English | MEDLINE | ID: covidwho-2306055

ABSTRACT

Polydimethylsiloxane (PDMS) has been widely used to make lab-on-a-chip devices, such as reactors and sensors, for biological research. Real-time nucleic acid testing is one of the main applications of PDMS microfluidic chips due to their high biocompatibility and transparency. However, the inherent hydrophobicity and excessive gas permeability of PDMS hinder its applications in many fields. This study developed a silicon-based polydimethylsiloxane-polyethylene-glycol (PDMS-PEG) copolymer microfluidic chip, the PDMS-PEG copolymer silicon chip (PPc-Si chip), for biomolecular diagnosis. By adjusting the modifier formula for PDMS, the hydrophilic switch occurred within 15 s after contact with water, resulting in only a 0.8% reduction in transmittance after modification. In addition, we evaluated the transmittance at a wide range of wavelengths from 200 nm to 1000 nm to provide a reference for its optical property study and application in optical-related devices. The improved hydrophilicity was achieved by introducing a large number of hydroxyl groups, which also resulted in excellent bonding strength of PPc-Si chips. The bonding condition was easy to achieve and time-saving. Real-time PCR tests were successfully conducted with higher efficiency and lower non-specific absorption. This chip has a high potential for a wide range of applications in point-of-care tests (POCT) and rapid disease diagnosis.

3.
Ageing Res Rev ; 87: 101921, 2023 06.
Article in English | MEDLINE | ID: covidwho-2252164

ABSTRACT

The complex structure of the blood-brain barrier (BBB) hinders its modeling and the treatment of brain diseases. The microfluidic technology promotes the development of BBB-on-a-chip platforms, which can be used to reproduce the complex brain microenvironment and physiological reactions. Compared with traditional transwell technology, microfluidic BBB-on-a-chip shows great technical advantages in terms of flexible control of fluid shear stress in the chip and fabrication efficiency of the chip system, which can be enhanced by the development of lithography and three-dimensional (3D) printing. It is convenient to accurately monitor the dynamic changes of biochemical parameters of individual cells in the model by integrating an automatic super-resolution imaging sensing platform. In addition, biomaterials, especially hydrogels and conductive polymers, solve the limitations of microfluidic BBB-on-a-chip by compounding onto microfluidic chip to provide a 3D space and special performance on the microfluidic chip. The microfluidic BBB-on-a-chip promotes the development of basic research, including cell migration, mechanism exploration of neurodegenerative diseases, drug barrier permeability, SARS-CoV-2 pathology. This study summarizes the recent advances, challenges and future prospects of microfluidic BBB-on-a-chip, which can help to promote the development of personalized medicine and drug discovery.


Subject(s)
COVID-19 , Microfluidic Analytical Techniques , Humans , Blood-Brain Barrier , Microfluidics , Microfluidic Analytical Techniques/methods , SARS-CoV-2
4.
Nano Today ; 48, 2023.
Article in English | Web of Science | ID: covidwho-2246240

ABSTRACT

Nucleic acid detection has been one of the most valued tools in point-of-care diagnostics from life science, agriculture, food safety and environmental surveillance, because of its high sensitivity, great specificity and simple operation. Since polymerase chain reactions (PCR) were discovered, more and more researchers attach importance to exploring ultrafast nucleic acid amplification methods for further expediting the process of detection and curbing infectious diseases' high spread rate, especially after the coronavirus disease 2019 (COVID-19) worldwide pandemic event. Nowadays, nanotechnology as one of the most cut-ting-edge technologies has aroused growing attention. In this review, we describe new advances in na-notechnology research for ultrafast nucleic acid amplification. We have introduced commonly used nanotechnologies, namely nanofluidics, nanoporous materials, nanoparticles and so on. Recent advances in these nanotechnologies for ultrafast sample pretreatments, accelerated enzymatic amplification and rapid heating/cooling processes was summarized. Finally, challenges and perspectives for the future applications of ultrafast nucleic acid amplification are presented.(c) 2022 Elsevier Ltd. All rights reserved.

5.
Trends Analyt Chem ; 158: 116871, 2023 Jan.
Article in English | MEDLINE | ID: covidwho-2242700

ABSTRACT

The coronavirus disease 2019 (COVID-19) has extensively promoted the application of nucleic acid testing technology in the field of clinical testing. The most widely used polymerase chain reaction (PCR)-based nucleic acid testing technology has problems such as complex operation, high requirements of personnel and laboratories, and contamination. The highly miniaturized microfluidic chip provides an essential tool for integrating the complex nucleic acid detection process. Various microfluidic chips have been developed for the rapid detection of nucleic acid, such as amplification-free microfluidics in combination with clustered regularly interspaced short palindromic repeats (CRISPR). In this review, we first summarized the routine process of nucleic acid testing, including sample processing and nucleic acid detection. Then the typical microfluidic chip technologies and new research advances are summarized. We also discuss the main problems of nucleic acid detection and the future developing trend of the microfluidic chip.

6.
TrAC - Trends in Analytical Chemistry ; 157 (no pagination), 2022.
Article in English | EMBASE | ID: covidwho-2236003

ABSTRACT

Polymerase chain reaction (PCR) amplifies specific fragment of DNA molecules and has been extensively applied in fields of pathogens and gene mutation detection, food safety and clinical diagnosis which on the other hand, holds the drawbacks of large size instrument, high heat dissipation etc. It has been demonstrated that microfluidics technique coupling with PCR reaction exhibits characteristics of integration, automatization, miniaturization, and portability. Meanwhile, various designed fabrication of microchip could contribute to diverse applications. In this review, we summarized major works about a variety of microfluidic chips equipped with several kinds of PCR techniques (PCR, RT-PCR, mPCR, dPCR) and detection methods like fluorescence, electrochemistry, and electrophoresis detection. The development and application of PCR-based microfluidic chip in pathogen and gene mutation detection, diseases prevention and diagnosis, DNA hybridization and low-volume sample treatment were also discussed. Copyright © 2022 Elsevier B.V.

7.
Biosensors (Basel) ; 13(2)2023 Feb 07.
Article in English | MEDLINE | ID: covidwho-2237489

ABSTRACT

Recently, infectious diseases, such as COVID-19, monkeypox, and Ebola, are plaguing human beings. Rapid and accurate diagnosis methods are required to preclude the spread of diseases. In this paper, an ultrafast polymerase chain reaction (PCR) equipment is designed to detect virus. The equipment consists of a silicon-based PCR chip, a thermocycling module, an optical detection module, and a control module. Silicon-based chip, with its thermal and fluid design, is used to improve detection efficiency. A thermoelectric cooler (TEC), together with a computer-controlled proportional-integral-derivative (PID) controller, is applied to accelerate the thermal cycle. A maximum of four samples can be tested simultaneously on the chip. Two kinds of fluorescent molecules can be detected by optical detection module. The equipment can detect viruses with 40 PCR amplification cycles in 5 min. The equipment is portable, easily operated, and low equipment cost, which shows great potential in epidemic prevention.


Subject(s)
COVID-19 , Microfluidic Analytical Techniques , Nucleic Acids , Viruses , Humans , Silicon , Microfluidics , Polymerase Chain Reaction/methods , Nucleic Acids/analysis , Nucleic Acid Amplification Techniques , Equipment Design
8.
J Biol Eng ; 16(1): 33, 2022 Dec 01.
Article in English | MEDLINE | ID: covidwho-2153614

ABSTRACT

The frequency of outbreaks of newly emerging infectious diseases has increased in recent years. The coronavirus disease 2019 (COVID-19) outbreak in late 2019 has caused a global pandemic, seriously endangering human health and social stability. Rapid detection of infectious disease pathogens is a key prerequisite for the early screening of cases and the reduction in transmission risk. Fluorescence quantitative polymerase chain reaction (qPCR) is currently the most commonly used pathogen detection method, but this method has high requirements in terms of operating staff, instrumentation, venues, and so forth. As a result, its application in the settings such as poorly conditioned communities and grassroots has been limited, and the detection needs of the first-line field cannot be met. The development of point-of-care testing (POCT) technology is of great practical significance for preventing and controlling infectious diseases. Isothermal amplification technology has advantages such as mild reaction conditions and low instrument dependence. It has a promising prospect in the development of POCT, combined with the advantages of high integration and portability of microfluidic chip technology. This study summarized the principles of several representative isothermal amplification techniques, as well as their advantages and disadvantages. Particularly, it reviewed the research progress on microfluidic chip-based recombinase polymerase isothermal amplification technology and highlighted future prospects.

9.
Biosensors (Basel) ; 12(10)2022 Sep 23.
Article in English | MEDLINE | ID: covidwho-2043580

ABSTRACT

The global pandemic of COVID-19 has created an unrivalled need for sensitive and rapid point-of-care testing (POCT) methods for the detection of infectious viruses. For the novel coronavirus SARS-CoV-2, the nucleocapsid protein (N-protein) is one of the most abundant structural proteins of the virus and it serves as a useful diagnostic marker for detection. Herein, we report a fiber optic particle plasmon resonance (FOPPR) biosensor which employed a single-stranded DNA (ssDNA) aptamer as the recognition element to detect the SARS-CoV-2 N-protein in 15 min with a limit of detection (LOD) of 2.8 nM, meeting the acceptable LOD of 106 copies/mL set by the WHO target product profile. The sensor chip is a microfluidic chip based on the balance between the gravitational potential and the capillary force to control fluid loading, thus enabling the power-free auto-flowing function. It also has a risk-free self-contained design to avoid the risk of the virus leaking into the environment. These findings demonstrate the potential for designing a low-cost and robust POCT device towards rapid antigen detection for early screening of SARS-CoV-2 and its related mutants.


Subject(s)
Biosensing Techniques , COVID-19 , Humans , SARS-CoV-2 , DNA, Single-Stranded , Microfluidics , COVID-19/diagnosis , Nucleocapsid Proteins/genetics
10.
Anal Bioanal Chem ; 414(28): 7957-7965, 2022 Nov.
Article in English | MEDLINE | ID: covidwho-2035028

ABSTRACT

SARS-CoV-2 has mutated many times since the onset of the COVID-19 pandemic, and the omicron is currently the most dominant variant. Determining the specific strain of the virus is beneficial in providing proper care and containment of the disease. We have previously reported a novel method of counting the number of particle immunoagglutination on a paper microfluidic chip using a smartphone-based fluorescence microscope. A single-copy-level detection was demonstrated from clinical saline gargle samples. In this work, we further evaluated two different SARS-CoV-2 monoclonal antibodies to spike vs. nucleocapsid antigens for detecting omicron vs. delta and spike vs. nucleocapsid proteins. The SARS-CoV-2 monoclonal antibody to nucleocapsid proteins could distinguish omicron from delta variants and nucleocapsid from spike proteins. However, such distinction could not be found with the monoclonal antibody to spike proteins, despite the numerous mutations found in spike proteins among variants. This result may suggest a clue to the role of nucleocapsid proteins in recognizing different variants.


Subject(s)
COVID-19 , SARS-CoV-2 , Humans , COVID-19/diagnosis , Spike Glycoprotein, Coronavirus , Pandemics , Microfluidics , Antibodies, Viral , Nucleocapsid Proteins/genetics , Immunoassay , Antibodies, Monoclonal
11.
Front Bioeng Biotechnol ; 10: 895236, 2022.
Article in English | MEDLINE | ID: covidwho-1952241

ABSTRACT

Ultrafast, portable, and inexpensive molecular diagnostic platforms are critical for clinical diagnosis and on-site detection. There are currently no available real-time polymerase chain reaction (PCR) devices able to meet the demands of point-of-care testing, as the heating and cooling processes cannot be avoided. In this study, the dual temperature modules were first designed to process microfluidic chips automatically circulating between them. Thus, a novel ultrafast molecular diagnostic real-time PCR device (approximately 18 and 23 min for DNA and RNA detection, respectively) with two channels (FAM and Cy5) for the detection of 12 targets was developed. The device contained three core functional components, including temperature control, optics, and motion, which were integrated into a portable compact box. The temperature modules accurately control temperature in rapid thermal cycles with less than ±0.1 °C, ±1 °C and ±0.5 °C for the temperature fluctuation, uniformity, and error of indication, respectively. The average coefficient of variation (CV) of the fluorescence intensity (FI) for all 12 wells was 2.3% for FAM and 2.7% for Cy5. There was a good linear relationship between the concentrations of fluorescent dye and the FIs of FAM and Cy5(R 2 = 0.9990 and 0.9937), and the average CVs of the Ct values calculated by the embedded software were 1.4% for FAM and Cy5, respectively. The 100 double-blind mocked sputum and 249 clinical stool samples were analyzed by the ultrafast real-time PCR device in comparison with the DAAN Gene SARS-CoV-2 kit run on the ABI 7500 instrument and Xpert C. difficile/Epi, respectively. Among the 249 stool samples, the ultrafast real-time PCR device detected toxigenic C. difficile in 54 samples (54/249, 21.7%) with a specificity and positive predictive values of 99.0 and 96.3%, which were higher than the Xpert C. difficile/Epi values of 94.4 and 88.1% (p > 0.05). The ultrafast real-time PCR device detected 15 SARS-CoV-2 positive samples, which has a 100% concordance with that obtained by the DAAN Gene SARS-CoV-2 kit. This study demonstrated that the ultrafast real-time PCR device integrated with microfluidic chips and dual temperature modules is an ultrafast, reliable, easy-to-use, and cost-effective molecular diagnostic platform for clinical diagnosis and on-site testing, especially in resource-limited settings.

12.
Biosens Bioelectron ; 210: 114293, 2022 Aug 15.
Article in English | MEDLINE | ID: covidwho-1797125

ABSTRACT

In the wake of a pandemic, the development of rapid, simple, and accurate molecular diagnostic tests can significantly aid in reducing the spread of infections. By combining particle imaging with molecular assays, a quick and highly sensitive biosensor can readily identify a pathogen at low concentrations. Here, we implement functionalized particle-enabled rotational diffusometry in combination with loop-mediated isothermal amplification for the rapid detection of the SARS-CoV-2 nsp2 gene in the recombinant plasmid as a proof of concept for COVID-19 diagnostics. By analyzing the images of blinking signals generated by these modified particles, the change in micro-level viscosity due to nucleic acid amplification was measured. The high sensitivity of rotational diffusometry enabled facile detection within 10 min, with a limit of detection of 70 ag/µL and a sample volume of 2 µL. Tenfold higher detection sensitivity was observed for rotational diffusometry in comparison with real-time PCR. In addition, the system stability and the effect of temperature on rotational diffusometric measurements were studied and reported. These results demonstrated the utility of a rotational diffusometric platform for the rapid and sensitive detection of SARS-CoV-2 cDNA fragments.


Subject(s)
Biosensing Techniques , COVID-19 , COVID-19/diagnosis , DNA, Complementary , Humans , Molecular Diagnostic Techniques/methods , Nucleic Acid Amplification Techniques/methods , Pandemics , RNA, Viral/genetics , SARS-CoV-2/genetics , Sensitivity and Specificity
13.
Sheng Wu Gong Cheng Xue Bao ; 38(3): 943-960, 2022 Mar 25.
Article in Chinese | MEDLINE | ID: covidwho-1771822

ABSTRACT

Polymerase chain reaction (PCR) is the gold standard for nucleic acid amplification in molecular diagnostics. The PCR includes multiple reaction stages (denaturation, annealing, and extension), and a complicated thermalcycler is required to repetitively provide different temperatures for different stages for 30-40 cycles within at least 1-2 hours. Due to the complicated devices and the long amplification time, it is difficult to adopt conventional PCR in point-of-care testing (POCT). Comparing to conventional PCR, isothermal amplification is able to provide a much faster and more convenient nucleic acid detection because of highly efficient amplification at a constant reaction temperature provided by a simple heating device. When isothermal amplification is combined with microfluidics, a more competent platform for POCT can be established. For example, various diagnosis devices based on isothermal amplification have been used to rapidly and conveniently detect SARS-CoV-2 viruses. This review summarized the recent development and applications of the microfluidics-based isothermal amplification. First, different typical isothermal amplification methods and related detection methods have been introduced. Subsequently, different types of microfluidic systems with isothermal amplification were discussed based on their characteristics, for example, functionality, system structure, flow control, and operation principles. Furthermore, detection of pathogens (e.g. SARS-CoV-2 viruses) based on isothermal amplification was introduced. Finally, the combination of isothermal amplification with other new technologies, e.g. CRISPR, has been introduced as well.


Subject(s)
COVID-19 , Microfluidics , COVID-19/diagnosis , Humans , Nucleic Acid Amplification Techniques , Polymerase Chain Reaction , SARS-CoV-2/genetics
14.
Chinese Journal of Analytical Chemistry ; 50(1):25-38, 2022.
Article in Chinese | Web of Science | ID: covidwho-1667872

ABSTRACT

Digital polymerase chain reaction (PCR), as a nucleic acid detection technology with wide application prospect, has become one of the most accurate nucleic acid detection technology at present. Multiplex detection is an important direction for the development of digital PCR technique. With the development of microfluidic technology, multiplex digital PCR technique has become more and more mature. This paper reviewed the research progresses of multiplex digital PCR in recent years, especially summarized the implementation of multiplex digital PCR technique in the past five years, and introduced the application of multiplex digital PCR technique in hot areas such as liquid biopsy, transgenic detection, and SARS-Cov-2 detection. Finally, the issues and challenges faced by multiplex digital PCR technique were discussed and the future direction of the technology was foreseen.

15.
Micromachines (Basel) ; 13(2)2022 Jan 28.
Article in English | MEDLINE | ID: covidwho-1667244

ABSTRACT

In the context of the COVID-19 epidemic, enhancing the transport of analyte to a sensor surface is crucial for rapid detection of biomolecules since common conditions, including low diffusion coefficients, cause inordinately long detection times. Integrated microfluidic immunoassay chips are receiving increasing attention for their low sample volume and fast response time. We herein take advantage of asymmetric ICEO flow at a bipolar sinusoidal electrode to improve the rate of antibody binding to the reaction surface based on finite element modeling. Three different microfluidic cavities are proposed by changing the positions of the surface reaction area. We further investigate the relationship between binding enhancement and reaction surface positions, Damkohler number, and the voltage and frequency of the AC signal applied to the driving electrodes. Furthermore, the influence of the AC signal applied to the sinusoidal bipolar electrode on antigen-antibody-binding performance is studied in detail. Above all, the simulation results demonstrate that the microfluidic immune-sensor with a sinusoidal bipolar electrode could not only significantly improve the heterogeneous immunoassays but also enable efficient enhancement of assays in a selected reaction region within the micro-cavity, providing a promising approach to a variety of immunoassay applications, such as medical diagnostics and environmental and food monitoring.

16.
Optics in Health Care and Biomedical Optics XI 2021 ; 11900, 2021.
Article in English | Scopus | ID: covidwho-1621985

ABSTRACT

Acquisition of the genes encoding variable regions of paired heavy and light chains (VH:VL) is crucial, but it is a labor and cost-intensive process in traditional methods. This study presents a novel method in which all processing steps for acquiring natively paired VH:VL genes from single cells are finished in a single microfluidic chip. The microfluidic chip performs single-cell trap/in situ fluorescent examination of antibody specificity/cell lysis/gene amplification all at single-cell level. By a proof-of-concept validation of efficiently acquiring paired VH:VL genes of anti-RBD (which is a key protein of SARS-CoV-2 virus) mAbs from single hybridomas, the microfluidic chip has been proved capable of remarkably improving cell loss/human labor/time cost, and more importantly, determinacy of native VH:VL genes pairing which is one of the most decisive factors of effectiveness for antibody discovery. © 2021 SPIE.

17.
Micromachines (Basel) ; 12(12)2021 Dec 19.
Article in English | MEDLINE | ID: covidwho-1580576

ABSTRACT

A two-stage isothermal amplification method, which consists of a first-stage basic recombinase polymerase amplification (RPA) and a second-stage fluorescence loop-mediated isothermal amplification (LAMP), as well as a microfluidic-chip-based portable system, were developed in this study; these enabled parallel detection of multiplex targets in real time in around one hour, with high sensitivity and specificity, without cross-contamination. The consumption of the sample and the reagent was 2.1 µL and 10.6 µL per reaction for RPA and LAMP, respectively. The lowest detection limit (LOD) was about 10 copies. The clinical amplification of about 40 nasopharyngeal swab samples, containing 17 SARS-CoV-2 (severe acute respiratory syndrome coronavirus) and 23 measles viruses (MV), were parallel tested by using the microfluidic chip. Both clinical specificity and sensitivity were 100% for MV, and the clinical specificity and sensitivity were 94.12% and 95.83% for SARS-CoV-2, respectively. This two-stage isothermal amplification method based on the microfluidic chip format offers a convenient, clinically parallel molecular diagnostic method, which can identify different nucleic acid samples simultaneously and in a timely manner, and with a low cost of the reaction reagent. It is especially suitable for resource-limited areas and point-of-care testing (POCT).

18.
Bioengineered ; 13(1): 876-883, 2022 01.
Article in English | MEDLINE | ID: covidwho-1585254

ABSTRACT

This research has developed a method for rapid detection of SARS-CoV-2 N protein on a paper-based microfluidic chip. The chitosan-glutaraldehyde cross-linking method is used to fix the coated antibody, and the sandwich enzyme-linked immunosorbent method is used to achieve the specific detection of the target antigen. The system studied the influence of coating antibody concentration and enzyme-labeled antibody concentration on target antigen detection. According to the average gray value measured under different N protein concentrations, the standard curve of the method was established and the sensitivity was tested, and its linear regression was obtained. The equation is y = 9.8286x+137.6, R2 = 0.9772 > 0.90, which shows a high degree of fit. When the concentration of coating antibody and enzyme-labeled antibody were 1 µg/mL and 2 µg/mL, P > 0.05, the difference was not statistically significant, so the lower concentration of 1 µg/mL was chosen as the coating antibody concentration. The results show that the minimum concentration of N protein that can be detected by this method is 8 µg/mL, and the minimum concentration of coating antibody and enzyme-labeled antibody is 1 µg/mL, which has the characteristics of high sensitivity and good repeatability.


Subject(s)
Antigens, Viral/analysis , COVID-19 Serological Testing/instrumentation , Coronavirus Nucleocapsid Proteins/analysis , Coronavirus Nucleocapsid Proteins/immunology , Lab-On-A-Chip Devices , SARS-CoV-2/chemistry , SARS-CoV-2/immunology , Antibodies, Viral/immunology , Biomedical Engineering , COVID-19/diagnosis , COVID-19/immunology , COVID-19/virology , COVID-19 Serological Testing/methods , COVID-19 Serological Testing/standards , Coronavirus Nucleocapsid Proteins/standards , Enzyme-Linked Immunosorbent Assay/instrumentation , Enzyme-Linked Immunosorbent Assay/methods , Enzyme-Linked Immunosorbent Assay/standards , Humans , Lab-On-A-Chip Devices/standards , Lab-On-A-Chip Devices/statistics & numerical data , Microchip Analytical Procedures/methods , Microchip Analytical Procedures/standards , Microchip Analytical Procedures/statistics & numerical data , Paper , Phosphoproteins/analysis , Phosphoproteins/immunology , Phosphoproteins/standards
19.
Biosens Bioelectron ; 199: 113865, 2022 Mar 01.
Article in English | MEDLINE | ID: covidwho-1560782

ABSTRACT

Rapid and sensitive detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is critical for early diagnostics and timely medical treatment of coronavirus disease 2019 (COVID-19). However, current detection methods typically rely on expensive and bulky instrumentation. Here, we developed a simple, sensitive, instrument-free, CRISPR-based diagnostics of SARS-CoV-2 using a self-contained microfluidic system. The microfluidic chip integrates isothermal amplification, CRISPR cleavage, and lateral flow detection in a single, closed microfluidic platform, enabling contamination-free, visual detection. To simplify the operation and transportation of the device, we lyophilized the CRISPR reagents in the reaction chamber and pre-stored the liquid solutions in blisters. We employed a low-cost, portable hand warmer to incubate the microfluidic chip without the need for electricity. The self-contained microfluidic system can detect down to 100 copies of SARS-CoV-2 RNA. Further, we clinically validated our method by detecting 24 COVID-19 clinical nasopharyngeal swab samples, achieving excellent sensitivity (94.1%), specificity (100%), and accuracy (95.8%). This simple, sensitive, and affordable microfluidic system represents a promising tool for point-of-care diagnostics of COVID-19 and other infectious diseases.


Subject(s)
Biosensing Techniques , COVID-19 , CRISPR-Cas Systems , Humans , Microfluidics , Nucleic Acid Amplification Techniques , RNA, Viral/genetics , SARS-CoV-2 , Sensitivity and Specificity
20.
Adv Sci (Weinh) ; 8(23): e2103266, 2021 12.
Article in English | MEDLINE | ID: covidwho-1479368

ABSTRACT

Activation of endothelial cells following severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection is thought to be the primary driver for the increasingly recognized thrombotic complications in coronavirus disease 2019 patients, potentially due to the SARS-CoV-2 Spike protein binding to the human angiotensin-converting enzyme 2 (hACE2). Vaccination therapies use the same Spike sequence or protein to boost host immune response as a protective mechanism against SARS-CoV-2 infection. As a result, cases of thrombotic events are reported following vaccination. Although vaccines are generally considered safe, due to genetic heterogeneity, age, or the presence of comorbidities in the population worldwide, the prediction of severe adverse outcome in patients remains a challenge. To elucidate Spike proteins underlying patient-specific-vascular thrombosis, the human microcirculation environment is recapitulated using a novel microfluidic platform coated with human endothelial cells and exposed to patient specific whole blood. Here, the blood coagulation effect is tested after exposure to Spike protein in nanoparticles and Spike variant D614G in viral vectors and the results are corroborated using live SARS-CoV-2. Of note, two potential strategies are also examined to reduce blood clot formation, by using nanoliposome-hACE2 and anti-Interleukin (IL) 6 antibodies.


Subject(s)
Blood Coagulation/physiology , SARS-CoV-2/isolation & purification , Spike Glycoprotein, Coronavirus/metabolism , Angiotensin-Converting Enzyme 2/chemistry , Angiotensin-Converting Enzyme 2/genetics , Angiotensin-Converting Enzyme 2/metabolism , Antibodies/chemistry , Antibodies/immunology , Antibodies/metabolism , COVID-19/diagnosis , COVID-19/virology , Endothelial Cells/chemistry , Endothelial Cells/cytology , Endothelial Cells/metabolism , Fibrin/chemistry , Fibrin/metabolism , Genetic Vectors/genetics , Genetic Vectors/metabolism , Humans , Interleukin-6/immunology , Liposomes/chemistry , Microfluidics/methods , Mutation , Nanoparticles/chemistry , Platelet Aggregation , SARS-CoV-2/metabolism , Spike Glycoprotein, Coronavirus/analysis , Spike Glycoprotein, Coronavirus/genetics
SELECTION OF CITATIONS
SEARCH DETAIL